current location: Home » product » Solar central air conditioning

Solar central air conditioning

Product introduction:

1、The unit uses waste heat and waste heat for refrigeration,almost no energy is needed.Operation cost is very low;
2、Each chamber inside the unit is designed with vacuum insulation layer to reduce internal heat loss and improve unit efficiency;
3、The COP of low temperature hot water absorption lithium bromide refrigeration unit and 0.1MPa steam type absorption lithium bromide refrigeration unit is above 0.72;
4、The COP of vapor type (0.6 MPa, 0.8 MPa) absorption lithium bromide chiller is above 1.35;

Get a free quote

Welcome to visit the factory

Solar central air conditioning

Product introduction

Shandong Lucy New Energy Technology Co., Ltd. has been focusing on product innovation and performance improvement, constantly optimizing the structure and performance of absorption refrigeration units, and has made great progress in waste heat recovery and solar air conditioning. The company has the small absorption air-cooled chiller (5kW cooling power) and solar air-conditioning system which has been running for 10 years in China. The units are exported to Europe, Southeast Asia, America, Australia, West Asia and other regions and countries. 

 

Unit parameters

Technical parameters of integrated hot water central air conditioning unit

model number RXZ-11 RXZ-23 RXZ-35 RXZ-58 RXZ-115 RXZ-175 RXZ-230 RXZ-290 RXZ-350
Rated cooling capacity      kW 11.5 23 35 58 115 175 230 290 350
Hot water Hot water flow   m³/h 2.9 5.8 8.6 14.3 28.5 42.8 57.0 70.0 85.3
Import and export temperature 90 / 85℃
Import and export pipe diameter DN25 DN40 DN40 DN50 DN65 DN80 DN100 DN100 DN125
Pressure drop    MPa 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08
cold water Cold water flow     m³/h 2.0 4.0  6.0 10.0  20.0  30.0 40.0  50.0  60
Import and export temperature 15 / 10℃
Import and export pipe diameter DN25 DN25 DN32 DN50 DN65 DN65 DN80 DN80 DN100
Pressure drop    MPa 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08
power consumption       kW 1.0 1.7 2.3 2.8 5.3 10.0 13.8 17.5 21.2

Dimensions

length       mm 1500 1500 1900 2250 3500 * * * *
width        mm 1320 1320 1320 1320 1700 * * * *
height       mm 1810 1810 1810 2100 2400 * * * *
Shipping weight         kg  

 

 

 

 

 

 

 

 

 

* * * *

Note:

1. The above main machines include lithium bromide unit, computer control box and cooling unit,cooling tower, cold water pump, cooling water pump, hot water electric control valve, cold water and cooling water filter, vacuum pump, etc.

2. The fouling coefficient of refrigerant water is 0.086m2 ℃ / kW.

3.Wet bulb temperature: 27 ℃.

 

hot water absorption chiller 

model number RXZ-11 RXZ-23 RXZ-35 RXZ-58 RXZ-115 RXZ-175 RXZ-230 RXZ-290 RXZ-350
Rated cooling capacity     kW 11 23 35 58 115 175 230 290 350
Hot water Hot water flow   m³/h 2.9 5.8 8.6 14.3 28.5   42.8 57.0 70 85.3
Import and export temperature 90 / 85 ℃
Import and export pipe diameter DN25 DN40 DN40 DN50 DN65 DN80 DN100 DN100 DN125
Pressure drop    MPa 0.08 0.08   0.08 0.08 0.08 0.08 0.08 0.08 0.08
cold water Cold water flow     m³/h 2.0 4.0 6.0 10.0 20.0 30.0 40.0 50.0 60.0
Import and export temperature 15 / 10℃
Import and export pipe diameter DN25 DN25 DN40 DN50 DN65 DN65 DN80 DN100 DN100
Pressure drop    MPa 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08
Cooling water Cooling water flow     m³/h 5 10.0 15.0 25.0 50.0 75.0 100 .0 120.0 150.0
Import and export temperature 30℃
Import and export pipe diameter DN32 DN40 DN50 DN65 DN80 DN100 DN125 DN150 DN150
Pressure drop    MPa 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08

Dimensions

length       mm 1070 1070 1350 1820 2680 2360 3150 2880 3450
width        mm 930 930 880 1020 1060 1500 1500 1370 1370
height       mm 1650 1650 1630 1850 2050 2270 2270 2360 2360
power consumption       kW 0.6 0.6   0.6 0.7 0.7 0.9 1.1 1.3 1.3
Shipping weight       kg 950 950 1100 1800 3000 3814 4700 5100 5900

Note:

1. The host includes a lithium bromide unit, a computer control box, a vacuum pump, and an electric hot water regulating valve.

2. The fouling coefficient of refrigerant water is 0.086m2℃/KW.

working principle

Main principle of solar air conditioning: lithium bromide water absorption refrigeration device is mainly composed of generator, condenser, evaporator and absorber. Its basic working principle is as follows:

(1)The working heat source (such as steam, hot water and gas) is used to heat the dilute solution delivered from the absorber by the solution pump in the generator, and the water in the solution is evaporated.

(2)The water vapor enters the condenser and is condensed into refrigerant water by the cooling medium.

(3)The refrigerant water enters the evaporator by throttling,absorbs the heat of refrigerant water and becomes steam

(4)In the generator, the remaining concentrated solution enters into the absorber, mixes with the water vapor from the evaporator, absorbs the water vapor and returns to the original concentration and becomes a dilute solution. The dilute solution enters the generator again through the solution pump and continues to circulate.

Product advantages

1、The unit uses waste heat and waste heat for refrigeration,almost no energy is needed.Operation cost is very low;

2、Each chamber inside the unit is designed with vacuum insulation layer to reduce internal heat loss and improve unit efficiency;

3、The COP of low temperature hot water absorption lithium bromide refrigeration unit and 0.1MPa steam type absorption lithium bromide refrigeration unit is above 0.72;

4、The COP of vapor type (0.6 MPa, 0.8 MPa) absorption lithium bromide chiller is above 1.35;

5、The COP of direct fired absorption lithium bromide chiller is above 1.35;

6、Leak detection for five consecutive processes to ensure that the unit has no fault due to leakage;

7、High intelligent automatic control. The unit can be started up and shut down by "one key", with the function of fault alarm dilution and shutdown.

8、The control system directly or indirectly controls the cooling water pump, cooling water pump and cooling tower fan, which improves the overall efficiency of solar air conditioning system by 25%;

9、The color LCD touch screen is used in the computer automatic control, which can dynamically display the operating conditions of the unit. The screen has the function of fault recording and real-time recording of parameter operation curve.

10、The first-line brand control components are adopted: Omron CP1 series PLC, OmronLY2N-Jseries relay, Schneider IC65series circuit breaker, Schneider LC1-Dseries contactor, WEINVIEWtouch screen, WILO water pump of Germany. These components ensure the reliability of the control system hardware.

11、Fine workmanship ensures the service life of the unit is 23 years and 30 years.