Flue gas absorption refrigeration unit

Product introduction:

1、The unit uses waste heat and waste heat for refrigeration,almost no energy is needed.Operation cost is very low;
2、Each chamber inside the unit is designed with vacuum insulation layer to reduce internal heat loss and improve unit efficiency;
3、The COP of low temperature hot water absorption lithium bromide refrigeration unit and 0.1MPa steam type absorption lithium bromide refrigeration unit is above 0.72;
4、The COP of vapor type (0.6 MPa, 0.8 MPa) absorption lithium bromide chiller is above 1.35;

Get a free quote

Welcome to visit the factory

Flue gas absorption refrigeration unit

Product introduction

Shandong Lucy New Energy Technology Co., Ltd. has been focusing on product innovation and performance improvement, constantly optimizing the structure and performance of absorption refrigeration units, and has made great progress in waste heat recovery and solar air conditioning. The company now has absorption air-conditioning units (5kW cooling capacity), and solar air-conditioning systems (11 years) with longest operation time in China, It is exported to Europe, Southeast Asia, America, Australia, West Asia and other regions and countries.

type

energy

application 

standard product

hot water absorption chiller

hot water ,conduct oil(72-90 ºC)

solar energy generator industry waste heat.

assemble solar hot water absorption chiller

solar hot water (72-90 ºC)(72-90 ºC) school ,hall ,office, villa .
steam operate double effect absorption chiller steam (6bar ,8bar) plant station, industry waste steam
exhaust gas fired absorption chiller high temperature exhaust gas (≥175 ºC) generator , boiler exhaust gas
natural gas fired absorption chiller natural gas, gas ,biogas, diesel hospital, hall, hotel, office.
Non-standard models two stage absorption chiller low temperature hot water(≥65ºC) industry hot water or solar hot water
twin times absorption chiller big temperature in/out waste heat (90-70 ºC) waste industry heat
automatically change single /double effect absorption chiller automatically change single /double effect absorption chiller industry waste heat
steam operate single effect absorption chiller steam (1bar, 4bar) plant, paper mill, industry steam
exhaust &hot water absorption chiller generator jacket water and exhaust gas CCHP system
small type absorption air cooling and air cold chiller hot water (72-90 ºC) villa family


Flue gas absorption refrigeration unit

This kind of chiller mainly composed of high temperature generator, low temperature generator, condenser, evaporator, absorber, high temperature heat exchanger and low temperature heat exchanger.

Unit parameters

Flue gas absorption refrigeration unit

Model number

YQR- 58

YQR- 115

YQR- 230

YQR- 350

YQR- 580

YQR- 1150

YQR- 1450

YQR- 1750

YQR- 2300

Rated cooling capacity     kW

58 115 230 350 580 1150 1450 1750 2300
Smoke

flow     kg/h

450 870 1698 2547 4245 8490 10188 12735 16980

Inlet and outlet temperature

500/180℃

Import and export pipe diameter

120X250 180X250 250X400 350X550 350X700 350X700 380X700 400X880 500X900
cold water

Cold water flow  m³/h

10 20 40 60 100 200 240 300 400

Inlet temperature

12 / 7℃

Import and export pipe diameter

DN50 DN65 DN80 DN100 DN125 DN150 DN150 DN200 DN200

Pressure drop  MPa

0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08
Cooling water

Cooling water flow  m³/h

17.5 35 70 105 175 350 420 525 700

Inlet temperature

30℃

Import and export pipe diameter

DN50 DN65 DN100 DN125 DN150 DN200 DN250 DN250 DN300

Pressure drop   MPa

0.08 0.08 0.08 0.08 0.09 0.09 0.10 0.10 0.10
Dimensions

length        mm

1450 1850 2700 2305 3150 4700 5500 5700 6880

width         mm

1150 1600 2100 2305 2400 2800 2800 3150 3550

height        mm

1700 1900 2000 2280 2400 2600 2600 2920 3210

power consumption      kW

0.5 0.9  1.1 2.2 2.2 6.5 9.2 9.2 11.0

Shipping weight       kg

2000 2900 4700 6700 10400 20000 22000 25700 35000

Note:

The fouling of chilled water is 0.086㎡ ℃ / kW.

working principle

Lithium bromide water absorption refrigeration device is mainly composed of generator, condenser, evaporator and absorber. Its basic working principle is as follows:

(1) The working heat source (such as steam, hot water and gas) is used to heat the dilute solution delivered from the absorber by the solution pump in the generator, and the water in the solution was evaporated to be steam.

(2) The steam enters the condenser and was condensed into refrigerant water by the cooling medium.

(3) The refrigerant water enters the evaporator by throttling, absorbs the heat of refrigerant water and becomes steam.

(4) In the generator, the remaining concentrated solution enters into the absorber, mixes with the water vapor from the evaporator, absorbs the steam and returns to the original concentration and becomes a dilute solution. The dilute solution enters the generator again through the solution pump and continues to circulate.

Product advantages

1、The unit uses waste heat and waste heat for refrigeration,almost no energy is needed.Operation cost is very low;

2、Each chamber inside the unit is designed with vacuum insulation layer to reduce internal heat loss and improve unit efficiency;

3、The COP of low temperature hot water absorption lithium bromide refrigeration unit and 0.1MPa steam type absorption lithium bromide refrigeration unit is above 0.72;

4、The COP of vapor type (0.6 MPa, 0.8 MPa) absorption lithium bromide chiller is above 1.35;

5、The COP of direct fired absorption lithium bromide chiller is above 1.35;

6、Leak detection for five consecutive processes to ensure that the unit has no fault due to leakage;

7、High intelligent automatic control. The unit can be started up and shut down by "one key", with the function of fault alarm dilution and shutdown.

8、The control system directly or indirectly controls the cooling water pump, cooling water pump and cooling tower fan, which improves the overall efficiency of solar air conditioning system by 25%;

9、The color LCD touch screen is used in the computer automatic control, which can dynamically display the operating conditions of the unit. The screen has the function of fault recording and real-time recording of parameter operation curve.

10、The first-line brand control components are adopted: Omron CP1 series PLC, OmronLY2N-Jseries relay, Schneider IC65series circuit breaker, Schneider LC1-Dseries contactor, WEINVIEWtouch screen, WILO water pump of Germany. These components ensure the reliability of the control system hardware.