Steam-operated Single Effect Absorption chiller

Product introduction:

When the unit is working, the light solution in the absorber is transported to the heat exchanger a by the generating pump in two ways, and then enters the generator after heat exchange and temperature rise.When the dilute solution entering the generator was heated to the evaporate point by the working steam, the refrigerant steam is generated, which is go into the condenser through throttling, finally cooled into refrigerant water. The refrigerant water produced by the generators is combined by the condenser water collector and then led into the evaporator.

Get a free quote

Welcome to visit the factory

Steam-operated Single Effect Absorption chiller

Product introduction

When the unit is working, the light solution in the absorber is transported to the heat exchanger a by the generating pump in two ways, and then enters the generator after heat exchange and temperature rise.When the dilute solution entering the generator was heated to the evaporate point by the working steam, the refrigerant steam is generated, which is go into the condenser through throttling, finally cooled into refrigerant water. The refrigerant water produced by the generators is combined by the condenser water collector and then led into the evaporator.

The refrigerant water absorbs the heat of the refrigerant water in the evaporator and intensifies into water vapor. In the generators, the heavy solution enters the absorber and mixes with the water vapor from the evaporator. The water vapor is absorbed and recovered to the original concentration and becomes dilute solution. The dilute solution enters into the generator through the generator pump and continues to circulate.

Unit parameters

Technical Parameters of 0.1MPa Steam-operated Single Effect Absorption chiller

Model

XZ- 23

XZ- 35

XZ- 58

XZ- 115

XZ- 175

XZ- 230

XZ- 290

XZ- 350

XZ-465

Cooling Capacity      kW

23

35

58

115

175

230

290

350

465

Working

Steam

 

 

Steam Consumption   

47.6

72.5

120.1

238.1

362.3

476.2

600.4

724.6

962.7

Steam Pressure

0.1MPa

Inlet Dia.

DN32

DN32

DN32

DN32

DN50

DN50

DN50

DN50

DN50

Outlet Dia.

DN25

DN25

DN25

DN25

DN25

DN25

DN25

DN25

DN25

 

Chilled

Water

 

Flow rate   m³/h

4

6

10

20

30

40

50

60

80

Inlet/Outlet Temp.

12 / 7℃

Inlet / Outlet Dia.

DN32

DN40

DN40

DN50

DN50

DN65

DN65

DN80

DN100

Pressure Loss  MPa

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

 

Cooling

water

 

Flow rate m³/h

10

15

24

48

74

97

122

147

196

Inlet Temp.

32/37℃

Inlet / Outlet Dia.

DN40

DN50

DN65

DN80

DN80

DN100

DN150

DN150

DN175

Pressure Loss   MPa

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

Dimen

sion

Length   mm

1010

1010

1430

1800

2550

2755

3250

3250

3250

Width   mm

785

785

785

920

920

920

970

1110

1350

Height   mm

1622

1622

1622

1820

1820

1820

1990

2150

2150

Power  Consumption  kW

0.3

0.3

0.4

0.5

0.6

0.6

0.9

0.9

1.1

Shipping Weight       kg

720

820

860

1000

1500

1700

1800

1900

2000

Note:

1. Fouling factor for chiller water is 0.086m2℃/kW.

2.Condensation temperature: ≤85℃

 

 


Model

XZ- 580

XZ- 700

XZ- 930

XZ- 1150

XZ- 1450

XZ- 1750

XZ- 2300

XZ- 2900

XZ-3500

Cooling Capacity      kW

580

700

930

1150

1450

1750

2300

2900

3500

Working

Steam

Steam Consumption    kg/h  

1200.8

1449.3

1925.5

2381.0

3002.1

3623.2

4761.9

6004.1

7246.4

Steam Pressure

0.1MPa

Chilled

Water

Inlet Dia.

DN65

DN65

DN80

DN80

DN100

DN100

DN100

DN150

DN150

Outlet Dia.

DN40

DN40

DN65

DN65

DN80

DN80

DN80

DN100

DN100

Flow rate   m3/h

100

120

160

198

249

301

396

499

602

Inlet/Outlet Temp.

12 / 7℃

Inlet / Outlet Dia.

DN100

DN125

DN125

DN150

DN150

DN175

DN200

DN250

DN300

 

Pressure Loss  MPa

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

 

Cooling

water

 

Flow rate  m3/h

244

295

392

484

611

737

969

1222

1474

Inlet Temp.

32/37℃

Inlet / Outlet Dia.

DN200

DN175

DN175

DN300

DN350

DN350

DN400

DN400

DN450

Pressure Loss   MPa

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

0.1

Dimen

sion

Length             mm

3105

3470

4100

5300

5400

5400

6000

6450

7100

Width             mm

1160

1300

1300

1300

1600

2000

2000

2300

2300

Height             mm

2100

2200

2300

2400

2400

2753

2753

2800

3200

Power  Consumption      kW

1.1

1.5

1.7

2.5

4.3

5.6

6.5

6.5

7

Shipping Weight         kg

5300

6700

8000

9300

12800

16000

20500

27000

32000

 

 

 

 

 

 

 

 

 

 

 

Note:

1. Fouling factor for chiller water is 0.086m2℃/kW.

2.Condensation temperature: ≤85℃

working principle

Product advantages

The refrigerant water absorbs the heat of the refrigerant water in the evaporator and intensifies into water vapor. In the generators, the heavy solution enters the absorber and mixes with the water vapor from the evaporator. The water vapor is absorbed and recovered to the original concentration and becomes dilute solution. The dilute solution enters into the generator through the generator pump and continues to circulate